[[File: | [[File: Hook shaft front.jpg|left|thumb|alt=Oil the main shaft bearings at the two locations indicated on the machine|Oil the main shaft bearings at the two locations indicated on the machine]] [[File: Hook shaft back.jpg|center|thumb|alt=Oil the main shaft bearings at the two locations indicated on the machine|Oil the main shaft bearings at the two locations indicated on the machine]] |
Revision as of 17:30, 17 October 2013
To ensure your Butterfly embroidery machine enjoys a long and healthy life, it is important to oil the machine at the required intervals. However, please take care not to over-oil the machine as oil can accumulate and potentially get into the electronics, onto garments and/or other parts of the machine that were not designed to be oiled.
When oiling the Butterfly machine, standard sewing or embroidery machine oil should be used. It is recommended to oil the machine after each shift to give the oil time to settle. When starting the machine at the next shift for the first time, it is recommended to sew a sample run and to sew each run using Solvy. Solvy helps to catch any excess oil from dripping on and staining garments.
It is also not recommended to oil parts of the machine that are not specified in this guide.
Front needle springs
Oil the front needle springs once every twenty (20) hours of embroidery machine operation. Oil each bar through the slotted opening. Do not place more than one drop per bar per eight hour shift. There is a piece of felt material inside the head that absorbs the oil and lubricates the shaft.
Main shaft bearings
There are two stickers on either side of the main shaft along with an opening to easily add oil. Oil as indicated on the sticker.