Difference between revisions of "Tajima TMFD Electronics"
Line 17: | Line 17: | ||
List of boards generally found on the Tajima TMFD models: | List of boards generally found on the Tajima TMFD models: | ||
{{tajima Boards TME-DC TME-HC TMFD}} | |||
==Troubleshooting and Error Messages== | ==Troubleshooting and Error Messages== |
Revision as of 13:36, 7 September 2013
{{#invoke:Infobox|infobox}} The Tajima TMFD was one of the longest produced Tajima models.
TMFD Electronics
The Tajima TMFD machine electronics consist of the main power box, control panel, DU-10 (XY) and various other small boards such as head cards and joint cards.
List of boards generally found on the Tajima TMFD models:
Troubleshooting and Error Messages
The Tajima TMFD machine can produce the following error messages
- Tajima Error 211
- Main shaft not at fixed position. Spin manually or use the ATH function.
- Tajima Error 225
- Stitching outside of cap frame space.
- Tajima Error 281
- Color change cannot reach needle position. Check for bind. Check potentiometer.
- Tajima Error 291
- Thread break.
- Tajima Error 2B1
- Tape reader error. No reader is detected.
- Tajima Error 2B2
- Tape reader error. Data is corrupted.
- Tajima Error 2B3
- Tape reader error. End code data is incorrect.
- Tajima Error 2B4
- Tape reader error. Data is out of order. Please reset all units.
- Tajima Error 2B5
- Sequin data has an error.
- Tajima Error 2B6
- Tape reader error. No data coming in.
- Tajima Error 2B7
- Please load data first.
- Tajima Error 2B8
- Trying to run machine while data is still loading.
- Tajima Error 2B9
- Memory writing error. Try erasing all memory.
- Tajima Error 2BA
- Memory full. Erase designs.
- Tajima Error 2BB
- Cannot frame back any more.
- Tajima Error 2BC
- No data in memory here.
- Tajima Error 2C2
- Incorrect option, please change.
- Tajima Error 2CE
- Beam sensor is tripped, make sure both mirrors are aligned.
- Tajima Error 311
- Main motor not spinning. Check the S-card if it is active. Check main shaft if it is bound. This error generally requires circuit board repair of the S-Card, contact PLRElectronics for repair information
- Tajima Error 312
- Main shaft encoder giving incorrect signal. Check connections.
- Tajima Error 316
- The S-card is giving an error signal. Check card.
- Tajima Error 322
- The X-card is giving an error signal. Check card. This error generally requires circuit board repair of the X-Card, contact PLRElectronics for repair information
- Tajima Error 323
- The Y-card is giving an error signal. Check card. This error generally requires circuit board repair of the Y-Card, contact PLRElectronics for repair information
- Tajima Error 382
- Color change motor is not moving. Check for binds. Check connections.
- Tajima Error 383
- The color change location is not valid for running the head. Please check or re-center.
- Tajima Error 3D1
- Battery error. This error generally requires circuit board repair of the Control Panel, contact PLRElectronics for repair information
- Tajima Error 3D6
- CPU card detects problem with main program. Reinstall.
- Tajima Error B01
- Floppy disk format is not correct. Is the disk bad, or the floppy drive configured correctly?
- Tajima Error B02
- Floppy file system is not correct. Is the disk bad, or the floppy drive configured correctly?
- Tajima Error B03
- Floppy is marked as read-only.
- Tajima Error B04
- Floppy drive says no disk is inserted. Check drive configuration.
- Tajima Error BC1
- No Tajima designs found.
- Tajima Error BC2
- Cannot overwrite same name design.
- Tajima Error BC4
- Floppy write failed. Re-try.
- Tajima Error BC5
- Floppy disk is full.
- Tajima Error C01
- No response to floppy drive activation signal. Check drive configuration.
- Tajima Error 1B1
- Stop due to frame stepping.
- Tajima Error 1B2
- Stop due to stop code.
- Tajima Error 1B3
- Stop due to end of design.
- Tajima Error 1B4
- Stop due to thread trim.
- Tajima Error 1B5
- Stop due to sequin code.
- Tajima Error 1C1
- Stop due to stop button.
TMFD Electronics Repairs
PLRElectronics specialized in repair of all the Tajima TMFD electronics. Generally it is much cheaper to have the Tajima electronics repaired rather than buying very expensive new boards.
USB Upgrade
The USB Upgrade for the TMFD can be found at:
External Reader
The TMFD External Reader (Embroidery Black Box) can be purchased at: USB Flash Reader Embroidery Machine Transfer System
Internal Reader (Floppy to USB)